| Any unused product or waste material should be disposed of in accordance with local requirements. Humalog Mix25 100U/ml suspension for injection in vial Instructions for Use and Handling The vial is to be used in conjunction with an appropriate syringe (100 U markings).a) Vial - Preparing a doseVials containing Humalog Mix25 should be rotated in the palms of the hands before use to resuspend the insulin until it appears uniformly cloudy or milky. Do not shake vigorously as this may cause frothing which may interfere with the correct measurement of the dose. The vials should be examined frequently and should not be used if clumps of material are present or if solid white particles stick to the bottom or wall of the vial, giving it a frosted appearance.1. Wash your hands.2. If using a new vial, flip off the plastic protective cap, but do not remove the stopper.3. Draw air into the syringe equal to the prescribed Humalog Mix25 dose. Wipe the top of the vial with an alcohol swab. Put the needle through rubber top of the Humalog Mix25 vial and inject the air into the vial.4. Turn the vial and syringe upside down. Hold the vial and syringe firmly in one hand.5. Making sure the tip of the needle is in the Humalog Mix25, withdraw the correct dose into the syringe.6. Before removing the needle from the vial, check the syringe for air bubbles that reduce the amount of Humalog Mix25 in it. If bubbles are present, hold the syringe straight up and tap its side until the bubbles float to the top. Push them out with the plunger and withdraw the correct dose.7. Remove the needle from the vial and lay the syringe down so that the needle does not touch anything.b) Vial - Injecting a dose1. Choose a site for injection.2. Clean the skin as instructed.3. Stabilise the skin by spreading it or pinching up a large area. Insert the needle and inject as instructed.4. Pull the needle out and apply gentle pressure over the injection site for several seconds. Do not rub the area.5. Dispose of the syringe and needle safely.6. Use of the injection sites should be rotated so that the same is not used more than approximately once a month.Humalog Mix25 or Humalog Mix50 100U/ml suspension for injection in cartridges Instructions for Use and Handling Humalog Mix25 or Humalog Mix50 cartridges are to be used with a CE marked pen as recommended in the information provided by the device manufacturer.a) Cartridge - Preparing a doseCartridges containing Humalog Mix25 or Humalog Mix50 should be rotated in the palms of the hands ten times and inverted 180° ten times immediately before use to resuspend the insulin until it appears uniformly cloudy or milky. If not, repeat the above procedure until contents are mixed. Cartridges contain a small glass bead to assist mixing. Do not shake vigorously as this may cause frothing, which may interfere with the correct measurement of the dose.The cartridges should be examined frequently and should not be used if clumps of material are present or if solid white particles stick to the bottom or wall of the cartridge, giving a frosted appearance.Humalog Mix25 or Humalog Mix50 cartridges are not designed to allow any other insulin to be mixed in the cartridge. Cartridges are not designed to be refilled.The following is a general description. The manufacturer's instructions with each individual pen must be followed for loading the cartridge, attaching the needle and administering the insulin injection.b) Cartridge - Injecting a dose1. Wash your hands.2. Choose a site for injection.3. Clean the skin as instructed.4. Remove outer needle cap.5. Stabilise the skin by spreading it or pinching up a large area. Insert the needle as instructed.6. Press the knob.7. Pull the needle out and apply gentle pressure over the injection site for several seconds. Do not rub the area.8. Using the outer needle cap, unscrew the needle and dispose of it safely.9. Use of injection sites should be rotated so that the same site is not used more than approximately once a month.Humalog Mix25 or Humalog Mix50 100U/ml Pen, suspension for injection (excluding Kwikpen) Instructions for Use and Handling a) Pen - Preparing a dose1. Inspect the Humalog Mix25 or Humalog Mix50 100U/ml PenThe Pen should be rotated in the palms of the hands ten times and inverted 180° ten times immediately before use to resuspend the insulin until it appears uniformly cloudy or milky. If not, repeat the above procedure until contents are mixed. Cartridges contain a small glass bead to assist mixing. Do not shake vigorously as this may cause frothing, which may interfere with the correct measurement of the dose.The cartridges should be examined frequently and should not be used if clumps of material are present or if solid white particles stick to the bottom or wall of the cartridge, giving a frosted appearance.2. Put on the needle.Wipe the rubber seal with alcohol. Remove the paper tab from the capped needle. Screw the capped needle clockwise onto the pen until it is tight. Hold the pen with needle pointing up and remove the outer needle cap and inner needle cover.3. Priming Pen (check insulin flow).(a) The arrow should be visible in the dose window. If the arrow is not present, turn the dose knob clockwise until the arrow appears and notch is felt or visually aligned.(b) Pull dose knob out (in direction of the arrow) until a '0' appears in the dose window. A dose cannot be dialled until the dose knob is pulled out.(c) Turn dose knob clockwise until a '2' appears in the dose window.(d) Hold the pen with needle pointing up and tap the clear cartridge holder gently with your finger so any air bubbles collect near the top. Depress the injection button fully until you feel or hear a click. You should see a drop of insulin at the tip of the needle. If insulin does not appear, repeat the procedure until insulin appears.(e) Always prime the pen (check the insulin flow) before each injection. Failure to prime the pen may result in an inaccurate dose.4. Setting the dose.(a) Turn the dose knob clockwise until the arrow appears in the dose window and a notch is felt or visually aligned.(b) Pull the dose knob out (in the direction of the arrow) until a '0' appears in the dose window. A dose cannot be dialled until the dose knob is pulled out.(c) Turn the dose knob clockwise until the dose appears in the dose window. If too high a dose is dialled, turn the dose knob backward (anti-clockwise) until the correct dose appears in the window. A dose greater than the number of units remaining in the cartridge cannot be dialled.b) Pen - Injecting a dose1. Wash your hands.2. Choose a site for injection.3. Clean the skin as instructed.4. Remove outer needle cap.5. Stabilise the skin by spreading it or pinching up a large area. Insert the needle as instructed.6. Press the injection button down with the thumb (until you hear or feel a click); wait 5 seconds.7. Pull the needle out and apply gentle pressure over the injection site for several seconds. Do not rub the area.8. Immediately after an injection, use the outer needle cap to unscrew the needle. Remove the needle from the pen. This will ensure sterility, and prevent leakage, re-entry of air, and potential needle clogs. Do not reuse the needle. Dispose of the needle in a responsible manner. Needles and pens must not be shared. The pre-filled pen can be used until it is empty. Please properly discard or recycle.9. Replace the cap on the pen.10. Use of injection sites should be rotated so that the same site is not used more than approximately once a month.11. The injection button should be fully depressed before using the pen again.Humalog Mix25 or Humalog Mix50 100U/ml KwikPen, suspension for injection a) Instructions for use and handlingThe KwikPen should be rotated in the palms of the hands ten times and inverted 180° ten times immediately before use to resuspend the insulin until it appears uniformly cloudy or milky. If not, repeat the above procedure until contents are mixed. Cartridges contain a small glass bead to assist mixing. Do not shake vigorously as this may cause frothing which may interfere with the correct measurement of the dose.The cartridges should be examined frequently and should not be used if clumps of material are present or if solid white particles stick to the bottom or wall of the cartridge, giving a frosted appearance.b) Handling of the pre-filled penBefore using the KwikPen the user manual included in the package leaflet must be read carefully. The KwikPen has to be used as recommended in the user manual. | |